Our website is an independent, advertising-supported platform. We provide our content free of charge to our readers, and to keep it that way, we rely on revenue generated through advertisements and affiliate partnerships. This means that when you click on certain links on our site and make a purchase, we may earn a commission. Learn more.
How We Make Money
We sustain our operations through affiliate commissions and advertising. If you click on an affiliate link and make a purchase, we may receive a commission from the merchant at no additional cost to you. We also display advertisements on our website, which help generate revenue to support our work and keep our content free for readers. Our editorial team operates independently of our advertising and affiliate partnerships to ensure that our content remains unbiased and focused on providing you with the best information and recommendations based on thorough research and honest evaluations. To remain transparent, we’ve provided a list of our current affiliate partners here.

What Is a Shared Neutral?

By Geisha A. Legazpi
Updated May 17, 2024
Our promise to you
About Mechanics is dedicated to creating trustworthy, high-quality content that always prioritizes transparency, integrity, and inclusivity above all else. Our ensure that our content creation and review process includes rigorous fact-checking, evidence-based, and continual updates to ensure accuracy and reliability.

Our Promise to you

Founded in 2002, our company has been a trusted resource for readers seeking informative and engaging content. Our dedication to quality remains unwavering—and will never change. We follow a strict editorial policy, ensuring that our content is authored by highly qualified professionals and edited by subject matter experts. This guarantees that everything we publish is objective, accurate, and trustworthy.

Over the years, we've refined our approach to cover a wide range of topics, providing readers with reliable and practical advice to enhance their knowledge and skills. That's why millions of readers turn to us each year. Join us in celebrating the joy of learning, guided by standards you can trust.

Editorial Standards

At About Mechanics, we are committed to creating content that you can trust. Our editorial process is designed to ensure that every piece of content we publish is accurate, reliable, and informative.

Our team of experienced writers and editors follows a strict set of guidelines to ensure the highest quality content. We conduct thorough research, fact-check all information, and rely on credible sources to back up our claims. Our content is reviewed by subject-matter experts to ensure accuracy and clarity.

We believe in transparency and maintain editorial independence from our advertisers. Our team does not receive direct compensation from advertisers, allowing us to create unbiased content that prioritizes your interests.

A shared neutral, in electrical circuits, is a common connection for the neutral lines that usually carry a near zero net current. In the case of a three-phase circuit, the neutral line current for a balanced three-phase load is zero or very minimal. For split-phase electric power, when there are balanced loads on each of the two phases, there is almost zero net current on the common neutral wire. The shared neutral wire is also called a common neutral wire, and this arrangement is known as an Edison circuit.

Although the current in a shared neutral may be almost zero when the loads are balanced, it is important to use copper cables that can carry currents during a load imbalance. A similar situation happens for balanced three-phase loads when there is an interruption in current from one of the phases. This condition can be experienced when there is an unexpected open circuit on one of the three-phase loads.

In terms of distribution cost, it is more expensive to run single-phase wirings. In single-phase wirings, the hot and neutral will be required to provide the same current-carrying capacity. For instance, given a 1,000-watt (W) load, a 100-volt (V) supply line needs to run about 10 amperes (A). If a split-phase power line were to provide twice the power, the amount of cables needed increases by only 50% and not 100% because the split-phase power cabling will use a shared neutral, which will share the same neutral wire to two hot wires that provide a voltage that is out of phase with each other. The return currents on the neutral will cancel when each hot phase is feeding the same current to the load.

A typical three-phase motor will require five wires. These are the earth connection, the neutral connection, and the first-, second-, and third-phase connections, which are all "hot," or live. The earth connection may only have surge currents during normal transient conditions or during times of lightning storms. It is possible that surge currents can be produced through the three-phase lines caused by electromagnetic pulses from lightning.

If two three-phase motors are connected to the three-phase line, the neutral line can be a shared neutral between the two motors. Under normal conditions, there will be no current in the neutral wire. Circuit breakers are ganged three-phase breakers, thus any over-current at least one phase will trip the ganged breaker and disconnect all phases from the motor. This results in a mechanism for preventing the neutral current from increasing beyond a few milliamperes.