We are independent & ad-supported. We may earn a commission for purchases made through our links.
Advertiser Disclosure
Our website is an independent, advertising-supported platform. We provide our content free of charge to our readers, and to keep it that way, we rely on revenue generated through advertisements and affiliate partnerships. This means that when you click on certain links on our site and make a purchase, we may earn a commission. Learn more.
How We Make Money
We sustain our operations through affiliate commissions and advertising. If you click on an affiliate link and make a purchase, we may receive a commission from the merchant at no additional cost to you. We also display advertisements on our website, which help generate revenue to support our work and keep our content free for readers. Our editorial team operates independently of our advertising and affiliate partnerships to ensure that our content remains unbiased and focused on providing you with the best information and recommendations based on thorough research and honest evaluations. To remain transparent, we’ve provided a list of our current affiliate partners here.

What are Ultrasonic Flowmeters?

By H.R. Childress
Updated May 17, 2024
Our promise to you
About Mechanics is dedicated to creating trustworthy, high-quality content that always prioritizes transparency, integrity, and inclusivity above all else. Our ensure that our content creation and review process includes rigorous fact-checking, evidence-based, and continual updates to ensure accuracy and reliability.

Our Promise to you

Founded in 2002, our company has been a trusted resource for readers seeking informative and engaging content. Our dedication to quality remains unwavering—and will never change. We follow a strict editorial policy, ensuring that our content is authored by highly qualified professionals and edited by subject matter experts. This guarantees that everything we publish is objective, accurate, and trustworthy.

Over the years, we've refined our approach to cover a wide range of topics, providing readers with reliable and practical advice to enhance their knowledge and skills. That's why millions of readers turn to us each year. Join us in celebrating the joy of learning, guided by standards you can trust.

Editorial Standards

At About Mechanics, we are committed to creating content that you can trust. Our editorial process is designed to ensure that every piece of content we publish is accurate, reliable, and informative.

Our team of experienced writers and editors follows a strict set of guidelines to ensure the highest quality content. We conduct thorough research, fact-check all information, and rely on credible sources to back up our claims. Our content is reviewed by subject-matter experts to ensure accuracy and clarity.

We believe in transparency and maintain editorial independence from our advertisers. Our team does not receive direct compensation from advertisers, allowing us to create unbiased content that prioritizes your interests.

Ultrasonic flowmeters measure water or other liquids, and, in some cases, gases, flowing through pipes. These meters can measure both the velocity and the volumetric flow of a liquid. They are simple to use because, unlike most types of meters, ultrasonic flowmeters clamp onto the pipes rather than being installed inside them, so the flow does not have to be interrupted to install one.

There are two main types of ultrasonic flowmeter — transit-time flowmeters and Doppler flowmeters. Both types clamp onto the outside of the pipes, but they differ in the method used to measure the flow, and each method has its own advantages and disadvantages. Transit-time flowmeters work better for clean liquids, which do not have many air bubbles or solid particles. Doppler flowmeters, by contrast, require that the liquid has bubbles or particles in it in order to measure the flow, but they also require the liquid to be moving at or above a certain speed.

Transit-time ultrasonic flowmeters, also called transmission flowmeters, use a principle called phase shifting. Two transducers, which both send and receive ultrasonic energy beams, are positioned some distance apart from each other on the pipe. The meter measures the amount of time it takes the energy to travel in each direction, and finds the difference between the two times. This difference is directly proportional to the velocity of the liquid, which is calculated by the flowmeter each time it takes a measurement.

Doppler ultrasonic flowmeters make use of the Doppler effect, which states that the frequency of sound waves depends upon how both the source and the observer of the sound are moving. Like transit-time meters, Doppler varieties use two transducers, but one transducer only sends and the other only receives. The sending transducer sends out ultrasonic energy beams, and particles or bubbles in the liquid cause the frequency of the beams to change. This shift in frequency is measured by the receiving transducer, and it is proportional to the velocity of the liquid.

Ultrasonic flowmeters are versatile, as they can measure the flow of several different liquids, including not only water but sewage water, oils, and liquids that are produced by industrial processes. These meters are most commonly used to measure flow in pipes, but they can also be used to measure it in open channels. This is done by measuring the water level in the channel, which can then be related to the volumetric flow.

About Mechanics is dedicated to providing accurate and trustworthy information. We carefully select reputable sources and employ a rigorous fact-checking process to maintain the highest standards. To learn more about our commitment to accuracy, read our editorial process.
Discussion Comments
About Mechanics, in your inbox

Our latest articles, guides, and more, delivered daily.

About Mechanics, in your inbox

Our latest articles, guides, and more, delivered daily.